Part Number Hot Search : 
ML145406 00BGXC 25YXXX M44276F M2114 C106MS LPT66 H11L2MTV
Product Description
Full Text Search
 

To Download KBU6G Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 KBU6A ... KBU6M
KBU6A ... KBU6M
Silicon-Bridge-Rectifiers Silizium-Bruckengleichrichter Version 2005-10-21
5.7 5.8 23.5
4
Nominal current Nennstrom Alternating input voltage Eingangswechselspannung Plastic case Kunststoffgehause Weight approx. Gewicht ca. Plastic material has UL classification 94V-0 Gehausematerial UL94V-0 klassifiziert Standard packaging bulk Standard Lieferform lose im Karton
6A 35...700 V 23.5 x 5.7 x 19.3 [mm] 7g
KBU ...
3.3 1
1.2 5.08
Dimensions - Mae [mm]
Recognized Product - Underwriters Laboratories Inc.(R) File E175067 Anerkanntes Produkt - Underwriters Laboratories Inc.(R) Nr. E175067
Maximum ratings Type Typ KBU6A KBU6B KBU6D KBU6G KBU6J KBU6K KBU6M Repetitive peak forward current Periodischer Spitzenstrom Peak forward surge current, 50/60 Hz half sine-wave Stostrom fur eine 50/60 Hz Sinus-Halbwelle Rating for fusing, t < 10 ms Grenzlastintegral, t < 10 ms Operating junction temperature - Sperrschichttemperatur Storage temperature - Lagerungstemperatur Admissible torque for mounting Zulassiges Anzugsdrehmoment Max. alternating input voltage Max. Eingangswechselspannung VVRMS [V] 35 70 140 280 420 560 700 f > 15 Hz TA = 25C TA = 25C IFRM IFSM i2t Tj TS M4
25 min.
19.3
6
Grenzwerte Repetitive peak reverse voltage Periodische Spitzensperrspannung VRRM [V] 1) 50 100 200 400 600 800 1000 40 A 2) 230/250 A 260 A2s -50...+150C -50...+150C 9 10% lb.in. 1 10% Nm
1 2
Valid for one branch - Gultig fur einen Bruckenzweig Valid, if leads are kept at ambient temperature TA = 50C at a distance of 5 mm from case Gultig, wenn die Anschlussdrahte in 5 mm vom Gehause auf Umgebungstemperatur TA = 50C gehalten werden http://www.diotec.com/
(c) Diotec Semiconductor AG
1
KBU6A ... KBU6M Characteristics Max. rectified current without cooling fin Dauergrenzstrom ohne Kuhlblech Max. rectified current with cooling fin 300 cm Dauergrenzstrom mit Kuhlblech 300 cm2 Forward voltage - Durchlass-Spannung Leakage current - Sperrstrom Thermal resistance junction to case Warmewiderstand Sperrschicht - Gehause TA = 50C TA = 50C Tj = 25C Tj = 25C R-load C-load R-load C-load IF = 6 A VR = VRRM IFAV IFAV IFAV IFAV VF IR RthC Kennwerte 4.2 A 1) 3.4 A 1) 6.0 A 4.8 A < 1.0 V 2) < 10 A < 3.3 K/W
Type Typ KBU6A KBU6B KBU6D KBU6G KBU6J KBU6K KBU6M
Max. admissible load capacitor Max. zulassiger Ladekondensator CL [F] 20000 10000 5000 2500 1500 1000 800
Min. required protective resistor Min. erforderl. Schutzwiderstand Rt [] 0.25 0.5 1.0 2.0 3.0 4.0 5.5
120 [%] 100
103
[A]
102 80 10
Tj = 125C
60
Tj = 25C
40 1 20 IFAV 0 0 TA 50 100 150 [C] IF 10
-1
250a-(7.5a-1,05v)
0.4
VF
0.8
1.0
1.2
1.4
[V] 1.8
Rated forward current versus ambient temperature Zul. Richtstrom in Abh. von der Umgebungstemp.
Forward characteristics (typical values) Durchlasskennlinien (typische Werte)
1 2
Valid, if leads are kept at ambient temperature at a distance of 5 mm from case Gultig, wenn die Anschlussdrahte in 5 mm Abstand vom Gehause auf Umgebungstemperatur gehalten werden Valid for one branch - Gultig fur einen Bruckenzweig http://www.diotec.com/ (c) Diotec Semiconductor AG
2


▲Up To Search▲   

 
Price & Availability of KBU6G

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .